• +31 (0) 594 696 131
  • sales@eurotronbenelux.nl
  • Login
  • Home
  • products
      • Pressure Calibrators
      • Automatic Pressure Calibrators
      • Digital pressure indicators
      • Pressure Controllers
      • Multifunction Calibrators
      • Atex approved instruments
      • Nitrogen Sources
      • Hand Pumps
      • Loop Calibrators
      • Hart Communicators
      • Marine Calibration Kits
      • Temperature Calibrators
      • Temperature Probes
      • Software
      • Pressure Sensors
      • Pressure Gauges
      • Recorders
      • Temperature Sensors
      • Portable Flow Meters
      • Thermal Imagers
      • Gas Detection
      • Gas Emission Analysers
      • Humidity Calibrators
      • Relative moisture sensors
      • Dew point transmitters
      • Signal conditioning
      • Infrared Temperature
      • Accessories
      • Testbenches
      • IoT Solutions
      • Pressure Modules
  • Brands
      • Druck
      • Additel
      • Process Sensing Technolgies / Michell Instruments
      • Ralston Instruments
      • PR Electronics
      • Eurotron Instruments
      • Optris
      • Wika
      • Fluke
      • MSA
      • Seitron
      • STIKO
      • Panametrics
      • Minimess
      • Setra
      • ERFI
      • AVIC
  • Rental
  • Calibration
  • Contact
  • item(s)
×

Request a quote

AM1710


AM1710
Home / Producten / AM1710

AM1710

Secondary Reference PRT

Price on request

The AM1710 series of Secondary Reference PRT offers affordable reference probes for precision temperature measurement and calibration both in the lab and in the field.

Request a quote

 
  • Product description
  • Extra information
  • Downloads
  • The AM1710 series of Secondary Reference PRT offers affordable reference probes for precision temperature measurement and calibration both in the lab and in the field. These PRTs feature an accuracy of <0.012°C and a short term stability of <0.007°C.

    To reach the best performance in stability and repeatability, the sensing element has been specially designed to protect the platinum sensing wire from contamination at high temperatures. A unique supporting structure and filling material provide the best balance among the hysteresis effect, mechanical shock and thermal shock performance. This high performance probe fully meets the ITS-90 criteria for reference thermometers. Each probe comes standard with an ISO 17025 accredited calibration.

    • Temperature Range: -40°C to 160°C
    • Accuracy: <0.012°C at 0.01°C
    • Long Term Drift: <0.01°C
    • Short-term Stability: <0.007°C
    • Durable and Shock Resistant
    • Temperature Coefficient 0.003925ΩΩ/ Ω/ °C
    • Fully Meets the ITS-90 Criteria for Reference Thermometers
    • Stainless Steel Sheath
    • ISO 17025 Accredited Calibration Included
  • Specifications
     

     

    AM1710-12
    AM1710-BEND
    Temperature Range
    -40°C to 160°C
    Nominal Resistance at 0.01°C
    100 Ω
    Temperature Coefficient
    0.003925 Ω/Ω/°C
    Calibrated Accuracy (k=2)[1][2]
    ±0.025°C at -40°C
    ±0.015°C at 0.01°C
    ±0.025°C at 160°C
    Long Term Drift at 0.01°C[3]
    <0.01°C at TPW after 100 hours at 160°C
    Short Term Stability
    <0.007°C
    Thermal Shock
    <0.005°C after 10 thermal cycles from minimum to maximum temperatures
    Hysteresis
    ≤0.005°C
    Self-heating
    50 mW/°C
    Response Time[4]
    9 seconds

    Sheath Length
    12 in (305 mm)
    7 in (178 mm) from tip to bend
    4 in (101.6 mm) from bend to handle
    Sheath Diameter 0.25 in (6.35 mm)
    Sensor Element Length 1.26 in (32 mm)
    Sensor Element Location 0.12 in (3 mm) from tip
    Insulation Resistance
    >1000 MΩ at room temperature
    Sheath Material
    Stainless steel
    External Leads Teflon™ insulated copper wire, 4 leads, 6.5 feet (2 meters)
    Handle Dimension 0.59 in (15 mm) (OD) x 2.56 in (65 mm) (L) 0.59 in (15 mm) (OD) x 2.56 in (65 mm) (L)
    Handle Temperature Range
    -40°C to 160°C
    Calibration
    NIST-traceable calibration with data[5]

    [1] Includes calibration and 100 hour drift.
    [2] Probe calibration ranges may differ from probe temperature ranges (see Calibrated Accuracy for calibration ranges).
    [3] Long-term drift rate is for reference only. It could be affected by such facts as handling, application, and maintenance, etc.
    [4] For 63% response to step change in water moving at 1 meter per second.
    [5] For 17025 accredited calibration, please contact Additel. 

  • Documents:
    Filename Upload date Size
    Additel AccuMac AM1710 Datasheet 2025.6.26 0.5 MB
    Probe Selection Guide 2025.6.26 0.3 MB




     

Brands

  • > Druck
  • > Additel
  • > Process Sensing Technolgies / Michell Instruments
  • > Ralston Instruments
  • > PR Electronics
  • > Eurotron Instruments
  • > Optris
  • > Wika
  • > Fluke
  • > MSA
  • > Seitron
  • > STIKO
  • > Panametrics
  • > Minimess
  • > Setra
  • > ERFI
  • > AVIC
  • >

Rental

  • Did you know you can rent calibration and test & measureing equipment at Eurotron Intruments?
    • - Ideal for a temporary measuring project
    • - Measuring equipment needed for a short time
    • - Our measuring equipment is calibrated
    • - No need of an investment
    • - For specific measurings
    • - Always the most modern equipment available

About us

Eurotron is succesfull with different kind of products that are used on different and demanding markets: calibration equipment, pressure and temperature sensors, infrared thermometers and gasdetectors.

Customerservice

  • Privacy Policy
  • Shipment
  • General terms and conditions
  • Calibrationservices
  • Nieuwsbrief
  • Contact

BENEFITS

  • Wide range of products
  • Years of experience
  • Premium brands
  • In-house knowledge
  • Sale and rental
  • Private accountmanager
  • Worldwide delivery

Contact

sales@eurotronbenelux.nl
+31 (0) 594 696 131
Vossenkamp 7a 9351VR Leek
Netherlands

KvK Groningen 02098837
BTWnummer NL8179.84.859.B01

© 2025 Eurotron , All rights reserved | Developed by Pro Ontwerp

icon icon icon