• +31 (0) 594 696 131
  • sales@eurotronbenelux.nl
  • Login
  • Home
  • products
      • Pressure Calibrators
      • Automatic Pressure Calibrators
      • Digital pressure indicators
      • Pressure Controllers
      • Multifunction Calibrators
      • Atex approved instruments
      • Nitrogen Sources
      • Hand Pumps
      • Loop Calibrators
      • Hart Communicators
      • Marine Calibration Kits
      • Temperature Calibrators
      • Software
      • Pressure Sensors
      • Pressure Gauges
      • Recorders
      • Temperature Sensors
      • Portable Flow Meters
      • Thermal Imagers
      • Gas Detection
      • Gas Emission Analysers
      • Humidity Calibrators
      • Relative moisture sensors
      • Dew point transmitters
      • Signal conditioning
      • Infrared Temperature
      • Accessories
      • Testbenches
      • IoT Solutions
      • Pressure Modules
  • Brands
      • Druck
      • Additel
      • Process Sensing Technolgies / Michell Instruments
      • Ralston Instruments
      • PR Electronics
      • Eurotron Instruments
      • Optris
      • Wika
      • Fluke
      • MSA
      • Seitron
      • STIKO
      • Panametrics
      • Minimess
      • Setra
      • ERFI
      • AVIC
  • Rental
  • Calibration
  • Contact
  • item(s)
×

Request a quote

PTC255


PTC255
Home / Producten / PTC255

PTC255

Portable temperature calibrator

Price on request

The calibrators of the new Druck Premium Temperature Calibrator series are characterised by their unparalleled performance and outstanding ease of operation.

Request a quote

 
  • Product description
  • Extra information
  • Downloads
  • Druck temperature calibrators are used for the verification of the functionality and calibration of temperature measuring devices and temperature sensors with a special focus on long-term reliability and utmost accuracy in combination with easy operation.
    Every Druck temperature calibrator is meticulously tested for accuracy and stability. This is attested by our standard calibration certificate, which we issue with every temperature calibrator, or by means of an optional ISO 17025 calibration certificate. This is to guarantee that you receive a perfect product which can be traced back to national and international temperature measurement standards.

    Features

    Four functions in one temperature calibrator

     
    • Covering all calibration tasks with only one model: Dry block, infrared and surface calibration as well as calibration by means of a calibration bath
    • Cost savings due to a reduction in the number of versions required
    • Quick and easy change between the calibration functions
    • Additional calibration functions for your application
    • Dry block for aseptic sensors
    • Air Shield Insert for the best measurement uncertainties
    • Different media for liquid calibration

    Automatic calibration with camera

    In calibration processes for devices under test with their own temperature display, the display of the DUT must be read for each calibration point. The read value is transferred by the user to the calibrator or the calibration certificate, and the subsequent calibration point is only approached after a manual acknowledgement. For this purpose, the user must return to the calibrator at each calibration point. In some cases, this can lead to long delays if the user carries out other tasks in between. With our automatic calibration with a camera, these time-intensive intermediate steps are no longer needed:

    • The patented camera system automatically creates a recording of the DUT display at each calibration point. The subsequent calibration point is approached directly afterwards
    • No user interaction is required during the calibration process, as it is implemented automatically
    • All test points are approached without waiting times
    • Upon completion of the entire calibration process, the user transmits the data of the created display records to the calibrator or calibration certificate
    • During the entire calibration process, the user is free to carry out other tasks
    • ​The visual records of the device under test display at each calibration point are saved and attached to the calibration certificate as verification
  • Technical data

    PTC255 / PTC255i
    Temperature range Room temperature...255 °C Room temperature...491 °F
    Dimension for thecalibration insert Ø 60 x 170 mm (calibration insert easily exchangeable)
    Dry block Air Shield Insert External reference temperature sensor
    Display accuracy ±0.08 °C ±0.144 °F
    Temperature stability ±0.010 °C 0.018 °F
    Temperaturedistribution
     Axial
     Radial
     
    ±0.080 °C
    ±0.050 °C
     
    ±0.144 °F
    ±0.009 °F
    Influence of load ±0.025 °C 0.045 °F
    Dry block External reference temperature sensor Internal reference temperature sensor
    Display accuracy ±0.25 °C ±0.45 °F ±0.5 °C ±0.9 °F
    Temperature stability ±0.020 °C ±0.036 °F ±0.05 °C ±0.09 °F
    Temperaturedistribution
     Axial
     Radial
     
    ±0.300 °C
    ±0.150 °C
     
    ±0.540 °F
    ±0.270 °F
     
    ±0.300 °C
    ±0.150 °C
     
    ±0.540 °F
    ±0.270 °F
    Influence of load ±0.100 °C ±0.180 °F ±0.450 °C ±0.810 °F
    Calibration bath(stirred), tubinsert External reference temperature sensor Internal reference temperature sensor
    Display accuracy ±0.35 °C 0.63 °F ±0.53 °C 0.954 °F
    Temperature stability ±0.05 °C 0.09 °F ±0.100 °C 0.180 °F
    Temperaturedistribution
     Axial
     Radial
     
    ±0.300 °C
    ±0.150 °C
     
    0.540 °F
    0.270 °F
     
    ±0.300 °C
    ±0.150 °C
     
    0.540 °F
    0.270 °F
    Influence of load ±0.100 °C ±0.180 °F ±0.400 °C ±0.720 °F
    Calibration bath(stirred), directfilling External reference temperature sensor Internal reference temperature sensor
    Display accuracy ±0.18 °C ±0.324 °F ±0.46 °C ±0.828 °F
    Temperature stability ±0.040 °C ±0.072 °F ±0.050 °C ±0.090 °F
    Temperaturedistribution
     Axial
     Radial
     
    ±0.150 °C
    ±0.150 °C
     
    ±0.270 °F
    ±0.270 °F
     
    ±0.150 °C
    ±0.150 °C
     
    ±0.270 °F
    ±0.270 °F
    Influence of load ±0.100 °C ±0.180 °F ±0.400 °C ±0.720 °F
    Infrared calibration External reference temperature sensor Internal reference temperature sensor
    Display accuracy ±0.5 °C ±0.9 °F ±0.5 °C ±0.9 °F
    Temperature stability ±0.05 °C ±0.09 °F ±0.05 °C ±0.09 °F
    Emission factor 0.9994
    Surface calibration External reference temperature sensor
    Display accuracy ±1 °C ±1.8 °F
    Temperature stability ±0.2 °C ±0.36 °F


    Temperature calibrator PTC255i: integrated measuring instrument Technical data

    TC255 / PTC255i
    Heating time 
    20 °C…245 °C
    20 °C…255 °C
    68...473 °F
    68...491 °F
    15 min
    17 min
    Cooling time
    225 °C…30 °C 491...86 °F 50 min
    Resolution of the temperature display 0.1 / 0.01 / 0.001 °C (selectable) 0.1/0.01/0.001 °F (selectable)
    Hysteresis  ±0.010 °C ±0.018 °F
    Temperature units °C / °F / K (selectable)
    Reference temperature sensor internal, fixed installation / external (selectable)
    Interfaces Ethernet, 3 x USB 
    Connectivity OPC UA, serial communication, HTTP. Details and further possibilities on request.
    Dimensions
    Width
    Height
    Depth
    210 mm
    330 + 50 mm (Handle)
    300 mm
    Weight  Approx. 8.5 kg
    Power supply 100...115 V 60 Hz / 230 V 50 Hz, Protective conductor (PE) needed 
    Power consumption Approx. 1000 W
    Adjustable temperature range 0...255 °C 32...491 °F
    Display Brilliant color touchscreen (7 inches), multi panel safety glass
    Approvals


    Temperature calibrator PTC165i: integrated measuring instrument Technical data

    Device under test inputs - resistance thermometers

    Number of channels

    2

    Connection

    4 mm safety socket, 4 per channel

    Connection type

    2-, 3-, 4-wire technology

    Resistance range

     Pt100

     Pt1000

     

    0…400 Ω

    0…4000 Ω

    Accuracy

     Pt100

     Pt1000

     

    ±0.03 °C

    ±0.06 °C

     

    ±0.054 °F

    ±0.108 °F

    Device under test inputs - thermocouple

    Number of channels

    2

    Connection

    2x thermocouple socket (mini)

    Measuring range

    -10…100 mV

    Accuracy cold junction

    ±0.3 °C

    ±0.054 °F

    Accuracy

     Type K

     Type J

     Type N

     Type E

     Type T

     Type R

     Type S

     

    ±0.08 °C

    ±0.07 °C

    ±0.13 °C

    ±0.06 °C

    ±0.09 °C

    ±0.78 °C

    ±0.73 °C

     

    ±0.144 °F

    ±0.126 °F

    ±0.234 °F

    ±0.108 °F

    ±0.162 °F

    ±1.404 °F

    ±1.314 °F

    Standard signal input (current)

    Number of channels

    1

    Connection

    4 mm safety socket

    Measuring range

    0…24 mA

    Accuracy

    0.01 % of range

    Standard signal input (voltage)

    Number of channels

    1

    Connection

    4 mm safety socket

    Measuring range

    0…12 VDC

    Accuracy

    0.01 % of range

    Switch test

    Number of channels

    2

    Transmitter supply

    Output current

    Max. 24 mA

    Output voltage

    24 VDC

  • Documents:

    Documents Upload Date Size
    Druck PTC255_255i Datasheet 2025.1.28 3.1 MB
    Druck PTC255_255i User Manual 2024.8.18 4.3 MB

Brands

  • > Druck
  • > Additel
  • > Process Sensing Technolgies / Michell Instruments
  • > Ralston Instruments
  • > PR Electronics
  • > Eurotron Instruments
  • > Optris
  • > Wika
  • > Fluke
  • > MSA
  • > Seitron
  • > STIKO
  • > Panametrics
  • > Minimess
  • > Setra
  • > ERFI
  • > AVIC
  • >

Rental

  • Did you know you can rent calibration and test & measureing equipment at Eurotron Intruments?
    • - Ideal for a temporary measuring project
    • - Measuring equipment needed for a short time
    • - Our measuring equipment is calibrated
    • - No need of an investment
    • - For specific measurings
    • - Always the most modern equipment available

About us

Eurotron is succesfull with different kind of products that are used on different and demanding markets: calibration equipment, pressure and temperature sensors, infrared thermometers and gasdetectors.

Customerservice

  • Privacy Policy
  • Shipment
  • General terms and conditions
  • Calibrationservices
  • Nieuwsbrief
  • Contact

BENEFITS

  • Wide range of products
  • Years of experience
  • Premium brands
  • In-house knowledge
  • Sale and rental
  • Private accountmanager
  • Worldwide delivery

Contact

sales@eurotronbenelux.nl
+31 (0) 594 696 131
Vossenkamp 7a 9351VR Leek
Netherlands

KvK Groningen 02098837
BTWnummer NL8179.84.859.B01

© 2025 Eurotron , All rights reserved | Developed by Pro Ontwerp

icon icon icon